Configuration file - UPSIntegration section

Define one or more UPS units that can modify the behaviour of an Output.

In the context of the PowerController app a UPS is considered "healthy" or "unhealthy". An unhealthy UPS - - Is discharging and it's current battery charge and/or remaining runtime is below a set threshold (e.g. charge below 10%) - Is charging and it's current battery charge and/or remaining runtime is below a set threshold (e.g. charge below 90%)

Use this in conjunction with the UPSIntegration: entry in the Outputs section to dictate how an unhealthy UPS will override the state of the output.

Note: The section is optionaly, but if you use it, the required keys below are shown in bold.

Key Description
Name A name for this UPS. You will reference this name in the Outputs: UPSIntegration: UPS: entry.
Script The shell script to run to get this current state of the UPS. The script must return the information in JSON format to stdout. Can include a realtive or absolute path.
MinRuntimeWhenDischarging Minimum runtime remaining in seconds to when UPS is discharging to consider the UPS as "healthy".
MinChargeWhenDischarging Minimum charge remaining in percent when discharging to consider the UPS as "healthy".
MinRuntimeWhenCharging Minimum runtime remaining in seconds to when UPS is charging to consider the UPS as "healthy".
MinChargeWhenCharging Minimum charge remaining in percent when charging to consider the UPS as "healthy".

The UPS script should return a JSON object with the following format:

{
    "timestamp": "2024-06-01T12:00:00Z",
    "battery_state": "charging",
    "battery_charge_percent": 85,
    "battery_runtime_seconds": 600
}

Where:

  • battery_state is one of "charging", "discharging" or "charged"
  • battery_charge_percent is a number between 0 and 100
  • battery_runtime_seconds is the remaining runtime in seconds.

battery_charge_percent or battery_runtime_seconds can be null, but not both. See the shell_scripts/apc_ups_runtime.sh script as an example script for a retail APC UPS.